Item Dimension Unit
Structure COG
Size (Diagonal) 3.75 inch
Dot Matrix / Resolution 240 × 128 dots dots
Module Dimension 98.7 × 67.7 × 9.5 (MAX) mm
Viewing Area 92.0 × 53.0 mm
Active Area 83.975 × 44.775 mm
Dot / Pixel Size 0.325 × 0.325 mm
Dot / Pixel Pitch 0.35 × 0.35 mm
IC UC1608 or Equivalent
Interface 6800 / 8080 /SPI
Power Supply 3V
Duty 1/128 duty cycle
Type Graphic LCD Display
Pin No. Symbol Type Description
1 VB1- PWR LCD Bias Voltages. These are the voltage source to provide SEG driving currents. These voltages are generated internally. Connect capacitors of CBX between VBX+ and VBX–.
The resistance of these four traces directly affects the SEG driving strength of the resulting LCD module. Minimize the trace resistance is critical in achieving high quality image.
2 VB1+
3 VB0-
4 VB0+
5 VLCD PWR Main LCD Power Supply. Connect these pins together.
6 VBIAS I This is the reference voltage to generate the actual SEG driving voltage. VBIAS can be used to fine tune VLCD by external variable resistors. Internal resistor network has been provided to simplify external trimming circuit.
In COF application, connect a small bypass capacitor between VBIAS and VSS to reduce noise.
7 VSS PWR Ground
8 VDD PWR Supply Voltage for logic
9 D7 I/O Bi-directional bus for both serial and parallel host interfaces.
In serial modes, connect D[0] to SCK, D[3] to SDA,
Connect unused pins to VDD or VSS.
10 D6
11 D5
12 D4
13 D3
14 D2
15 D1
16 D0
17 WR1 I WR[1:0] controls the read/write operation of the host interface. See Host Interface section for more detail.
In parallel mode, WR[1:0] meaning depends on whether the interface is in the 6800 mode or the 8080 mode. In serial interface modes, these two pins are not used, connect them to VSS.
18 WR0
19 CD I Select Control data or Display data for read/write operation. In S9 mode, CD pin is not used. Connect CD to VSS when not used. ”L”: Control data ”H”: Display data
20 RST I When RST=”L”, all control registers are re-initialized by their default states.
Since UC1608x has built-in Power-ON-Reset and Software Reset command, RST pin is not required for proper chip operation. When RST is not used, connect the pin to VDD.
21 CS I Chip Select. The chip is selected when CS=”H”. When the chip is not selected, D[7:0] will be high impedance.
22 BM0 I Bus mode: The interface bus mode is determined by BM[1:0] and D[7:6] by the following relationship

240x128 COG Graphic LCD Module - RX240128A

Item Symbol Min Typ Max Unit
Operating Temperature TOP -20 - +70 ℃
Storage Temperature TST -30 - +80 ℃
Logic supply voltage VDD -0.3 - +4.0 V
LCD Generator supply voltage VDD2 -0.3 - +4.0 V
LCD Generated voltage VLCD -0.3 - +17.0 V
Item Symbol Condition Min Typ Max Unit
Supply Voltage For Logic VDD-VSS - 2.7 2.8~3.3 3.6 V
Supply Voltage For LCM VLCD Ta=-20℃
Ta=25℃
Ta=70℃
-
15.2
-
-
15.5
-
-
15.8
-
V
V
V
Input High Volt. VIH - 0.8 VDD - - V
Input Low Volt. VIL - - - 0.2 VDD V
Output High Volt. VOH - 0.8 VDD - - V
Output Low Volt. VOL - - - 0.2 VDD V
Supply Current(No include
LED Backlight)
IDD VDD=3.0V - 1.1 - mA
Top